Antwort How is a blower test done? Weitere Antworten – How does a blower test work

How is a blower test done?
After calibrating the device, the fan pulls air out of the house, lowering the air pressure inside. The higher outside air pressure then flows in through all unsealed gaps, cracks and openings such as gaps, cracks, or wiring penetrations.The sure way to pass a blower door test is to seal any openings, cracks, holes or penetrations that connect to the outside prior to ever installing the insulation, unless spray foam is used, which in addition to being a good insulation, is also an excellent sealer that is impermeable to air movement.Anyone thinking of buying a house or building one should consider having a blower door test performed. It will help determine the cost of future energy bills. The blower door test is a diagnostic tool used to measure the airtightness of a structure.

What is a good score on a blower door test : An ACH of 5 indicates a semi-airtight home and is a favorable result for older homes. ACH readings of 6 to 9 indicate a moderately leaky home. ACH readings over 9 indicate a very leaky home.

How long does a blower test take

approximately 1-2 hours

Generally, a blower door test, when combined with a whole home energy audit, should take approximately 1-2 hours. The blower door test itself can run for about a half an hour.

How much is a blower test : A blower door test costs around $325 on average, but you might pay between $200 and $450 , depending on a few different factors. This test is a great way to know whether your home is leaking precious heat or air conditioning, and the results can help you pinpoint those leaks and seal them.

Blower door test results are standardized for an air pressure difference of 50 Pa; better consistency and reproducibility occur at higher pressures.

If you're interested in having a blower door test conducted on your home, contact your local Dr. Energy Saver dealer today. We offer complete air sealing and insulation services to improve home performance.

How to read blower door results

Every 10 points on the blower door is about 1 square inch of air leak. So a 1400 cfm50 blower door number is about 1 square foot of air leakage across the whole home. That's not that much to chase, so every little bit counts. (1400/10 = 140 square inches/144 square inches/square foot = 1 square foot)CFM x 60 minutes in an hour/volume of the home=ACH50

Using the formula, 750 CFM x 60 minutes / 12,000 cubic feet = 3.75 ACH50. This home would pass the blower door test in some areas of the country where the test result must be 5 ACH50 or less, but not in others where the requirement is 3 ACH50 or less.You can hire a professional to perform a blower door test and energy audit for approximately $300-$400 for an average sized house. You also have the option to perform your own testing. More and more builders, remodelers, insulations companies, and HVAC companies are choosing to do them in-house.

Testing done at the higher end of the range (between 40 and 60 Pa) generally produces the most accurate results. Blower door test results are standardized for an air pressure difference of 50 Pa; better consistency and reproducibility occur at higher pressures.

How much is a blower door test : A blower door test costs around $325 on average, but you might pay between $200 and $450 , depending on a few different factors. This test is a great way to know whether your home is leaking precious heat or air conditioning, and the results can help you pinpoint those leaks and seal them.

What is an example of a blower door test : One example would be to isolate an area of the home that is causing an issue. If there is an upstairs bedroom that seems particularly warm in summer, a blower door test may reveal that the room is connected to the outside. It could be through an un-caulked window molding, or a light fixure.

How do you read a blower chart

How to Read a Fan Performance Curve

  1. Horizontal Bottom Axis = Air Volume Flow Rate (SCFM or m3/sec.)
  2. Vertical Left Axis = Static Pressure (inches water gauge [wg], pascals [Pa], or mm water gauge)
  3. Vertical Right Axis = Brake Horsepower (BHP or KW)


The blower door measures the airflow (CFM50 ) required to depressurize the house to -50 Pascals (~0.2 inches w.c.). This test condition is known as Untaped and is the basis for the Air Changes per Hour calculation, ACH50 = CFM50 x 60 / house volume.EXAMPLE: A house has a blower door reading of 1550 cfm. The volume of the home is 7,840 cubic feet. So for this house, the target blower door reduction is 25% To calculate the target blower door number, use the formula below: BD Target = BD Reading (cfm) X (1 – BD reduction goal %) BD Target = 1550 X .

How strong is 50 Pascals : A 50 Pascal pressure is roughly equivalent to the pressure generated by a 20 mph wind blowing on the building from all directions.